12
Using two „Extrude-Tite“ screws, fasten the KD Supply to the fastening bars (2) on the
front and back of the cooling unit
Position the power source over the KD Supply 2500 using a suitable hoisting device
Pull the power source connector as far as possible through the opening on the under-
side of the power source
Make connection between power source and cooling unit
CAUTION!
Risk of short circuit from kinked or damaged cables.
When positioning the KD Supply 2500, ensure that the cables are not kinked.
Carefully place power source on KD Supply 2500
Using two „Extrude-Tite“ screws, fasten the power supply to the fastening bars (1) on
the front and back of the KD Supply 2500.
CAUTION!
Danger from machines falling or toppling over.
Ensure that all screw connections are secure.
Establishing a Lo-
calNet connec-
tion between the
KD Supply 2500
and the power
source
Connect the power source and the KD
Supply 2500 using the LocalNet cable
supplied with the KD Supply 2500:
- Power source: LocalNet interface
- KD Supply 2500: LocalNet X9.1 inter-
face (front)
11