EasyManuals Logo

Fronius Primo User Manual

Fronius Primo
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
19
EN
Notes regarding the laying of data communication
cables
Laying data com-
munication ca-
bles
IMPORTANT! Operating the inverter with
one option card and two broken-out option
card slots is not permitted.
To cater for this eventuality, a suitable blan-
king cover (42,0405,2020) is available from
Fronius as an option.
IMPORTANT! Note the following if data communication cables are being introduced into
the inverter:
- depending on the number and cross-section of the data communication cables that
are being introduced, take the relevant blanking plugs out of the sealing insert and in-
sert the data communication cables.
- the relevant blanking plugs must be inserted into the free openings on the sealing in-
sert.

Other manuals for Fronius Primo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Primo and is the answer not in the manual?

Fronius Primo Specifications

General IconGeneral
CategoryInverter
AC nominal output3.0 - 8.2 kW
Grid frequency50 Hz / 60 Hz
THD< 3 %
Power factor (cos φac,r)0.85 - 1 ind./cap.
Efficiency98%
Max. input voltage1000 V
MPP voltage range240 - 800 V
Number of DC connections2
Number of MPP Trackers1
Dimensions (H x W x D)645 x 431 x 204 mm
Weight21.5 kg
Protection classIP65
Operating temperature range-40 °C to +60 °C
Warranty5 years
ModelPrimo
AC nominal voltage230 V