23
EN
(4) Stop/Start key
For interrupting and resuming the charging process
Confirms a menu item or setting
(5) "Battery cooled down" indicator (blue)
Indicates that a battery has cooled down and is ready for use
On steady: After charging has finished, the set cooling time or optionally the bat-
tery temperature has been reached.
Flashes every second: The water refill indicator has also tripped. More informa-
tion can be found under "Additional functions" in the "Display" section.
(6) "Fault" indicator (red)
On steady: The charger outputs an error. The current conditions do not allow prop-
er charge. While the red indicator is on, charging cannot take place (charging in-
terrupted). The relevant status code appears in the display.
Flashes briefly every 3 seconds: The charger outputs a warning. Charging is
continued despite the adverse charging parameters. The relevant status code and
the state of charge appear alternately on the display.
(7) "Charge" indicator (yellow)
On: During charging
Flashes: If charging has been interrupted
(8) "Battery charged" indicator (green)
On steady: Charging ended.
Flashes every second: Charging ended. The water refill indicator has also
tripped.