43
EN
- Stop:
normal ON:
- Charging is interrupted when an external switch is opened
- Or when the charging plug is disconnected by opening the auxiliary contacts
normal OFF:
- Opening of an external switch or the auxiliary contacts is ignored
- Button:
The function of the "Stop/Start" key can be simulated using an external button
- Contact detection:
ON:
- When Start Normal is ON, a battery is connected, and the external start/stop con-
tact is not closed, error 16 is set
- When Stop Normal is ON, charging has started, the external start/stop contact is
open, and the battery is not disconnected, error 16 is set
OFF:
- Contact detection is not performed
Refill Indicator:
The refill indicator is a message that appears as soon as the battery needs topping up with
distilled water. The time at which refilling is deemed necessary can be defined as follows:
- Every nth week and weekday
- e.g. top up with water every fortnight on a Friday
- If set to "off", the refilling request does not have to be confirmed
Option Section 1:
- Setting options:
- CAN1 (option box)
- Cool Bat Guide Easy (Fronius version only)
Option Section 2 (3kW only):
- Setting options:
- CAN2 (option box)
- Air-Puls (ECS)
Status outputs (3kW only):
- Setting for external lamp (normal or RGB)
Option Section: