113
EN
Replacing components on the front panel
Replacing the P-
display
Removing the P-display:
Remove the front panel (see the
"Opening the device" section)
Undo the three 4x9 TX20 tapping
screws (1)
Take the P-display out of the display
spacer frame
Installing the P-display:
Remove the protective film from the
new P-display
Place the new P-display on the display
spacer frame
Fit the P-display with three 4x9 tapping
screws (1)
[1 Nm]
Fit the front panel (see the "Closing the
device" section)
(1) (1) (1)
1
2
3
1
(1) (1) (1)
2
3
4

Table of Contents