120
Correctly thread the transformer 
connection (3) and the inductor 
connection (2)
Now fully insert the primary power mo-
dule and position it correctly
Insert the axial fan (5) in the strain-re-
lief device provided and connect it to 
the primary power module
Establish the ribbon cable connection 
(4) to the P-control
Fit the primary power module with five 
5x10 TX25 tapping screws (1) 
[3 Nm]
Fit the transformer connection with 
three 5x10 TX25 tapping screws (3) 
[4.5 Nm]
Fit the inductor connection with one 
5x10 TX25 tapping screw (2) 
[4.5 Nm]
Make sure the inductor leads are laid 
parallel and bind them with two type 
200 cable ties (10)
Fit the primary power module supply 
(L1, L2, L3, N) to the mains terminal
[1.5 Nm]
In case the assembly aid has been 
mounted, remove it
Fit the front panel and the AC connec-
ting plate (see the "Closing the device" 
section)
(5)
(4)(1)
(1)(1)
(1)(1) (2) (3) (3)
2
3
4
5
6
7
8
(10)
9
(L1)
(L2)
(L3)
(N)
10
11
12