The manufacturer's specifications for connection, installation, and operation must be ob-
served. You must carefully follow all installation steps and make all connections in accor-
dance with specifications and regulations to minimize any risk of danger.
The tightening torques for the respective terminals are listed in the Installation Instructions
for the devices.
Intended Use The inverter is designed exclusively to convert direct current from solar modules into alter-
nating current and feed this power into the public grid.
The following are deemed to be not in conformity with its intended purpose:
- Utilization for any other purpose, or in any other manner
- Alternations to the inverter are not expressly recommended by Fronius
- Installation of components that are not expressly recommended or sold by Fronius.
The manufacturer is not responsible for any damage resulting from improper use.
All warranty claims are considered void in such cases.
Proper use also means
- carefully reading and obeying the instructions and all the safety and danger notices in
the Operating and Installation Instructions
- compliance with the maintenance operations
- installation as specified in the Installation Instructions
When configuring the photovoltaic system, make sure that all components are operating
completely within their permitted operating range.
All measures recommended by the solar module manufacturer for maintaining solar mod-
ule properties must be followed.
Follow all grid operator regulations regarding grid power feed and connection methods.
Location Selec-
tion
Please note the following criteria when choosing a location for the inverter:
- Securely tighten all grounding terminals
(PE/ GND) using the proper torque
listed in the Operating Instructions, even
for free grounding terminals.
- Do not overload cables
- Check cables for damage and that they
are wired correctly
- Follow all safety instructions, Operating
Instructions, and any local connection
regulations and standards.
Always secure the inverter to the mounting
bracket with fixing screws using the torque
specified in the Operating Instructions.
Only put the inverter into operation with the
fixing screws securely tightened.
NOTE! Fronius will not bear any costs for loss of production, or installations, etc.,
which may arise due to a detected electric arc and its consequences.
Fronius accepts no liability for fires which may break out despite integrated arc
detection/interruption (e.g., due to a parallel arc).
NOTE! Before an inverter can be reset following a detected electric arc, check the
entire affected photovoltaic system for any damage.
3
2
2.5 Nm
1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo Advanced Series and is the answer not in the manual?

Fronius Symo Advanced Series Specifications

General IconGeneral
BrandFronius
ModelSymo Advanced Series
CategoryInverter
LanguageEnglish

Related product manuals