Energy fed into the public grid: 0 W
TARGET: 0W
0 W
500 W
1000 W
500 W
500 W
Example involving battery system without photovoltaics but with a second pro-
ducer within the home
Second producer in home network: 2000 W
Household consumption: 500 W
Target value set at feed-in point: 0 W
Power to the battery: 1500 W
Power consumed (AC) by inverter: 1500 W
Energy fed into the public grid: 0 W
TARGET: 0W
0 W
500 W
2000 W
1500 W
1500 W
Example involving battery system with a second producer within the home
PV system to Fronius Symo Hybrid: 1000 W
Second producer in home network: 2000 W
Household consumption: 500 W
Target value set at feed-in point: 0 W