Input signal
- Function of the: Ext Sig. / S0-Meter / OFF
Only with the Ext Sig.: function selected:
Triggering method: Warning (warning shown on display) / Ext. Stop (inverter
switches off)
Connection type: N/C (normally closed contact) / N/O (normally open contact)
SMS / relay
- Event delay:
for entering the time delay after which an SMS is sent or the relay is to switch
900 - 86,400 seconds
- Event counter:
for entering the number of events that lead to signalling:
10 - 255
Insulation setting
- Insulation warning: ON / OFF
- Threshold warning: for entering a threshold that leads to a warning
- Threshold fault: for entering a threshold that leads to a fault (not available in all
countries)
- Both the PV system and the battery are monitored
Temperature warning
For activating/deactivating the overtemperature warning for each event
ON / OFF
TOTAL Reset
Under the LOG menu item, this setting resets the max. and min. voltage values and
the max. power of feeding in to zero.
Once the values have been reset, this action cannot be undone.
To reset the values to zero, press the "Enter" key.
"CONFIRM" is displayed.
Press "Enter" again.
The values are reset and the menu is displayed