EasyManua.ls Logo

Fronius TransPuls Synergic 3200 - Changing Intermediate Circuit Capacitors (TS 4000;5000, TPS 3200;4000;5000); Removing Intermediate Circuit Capacitors

Fronius TransPuls Synergic 3200
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
113
EN
Changing intermediate circuit capacitors (TS 4000/
5000, TPS 3200/4000/5000)
1. Remove side panels
2. Loosen three screws (1) on rear of
housing (2)
3. Remove rear of housing (2)
Removing inter-
mediate circuit
capacitors
1. Loosen two screws (3) on cover
sheet (4)
2. Remove cover sheet (4)
Fig. 1 Removing rear of housing
(1)
(1)
(2)
Fig. 2 Removing cover sheet
1. Loosen four capacitor screws (5)
NOTE! When loosening capacitor nuts (6) - Fig.4 - hold the capacitors (7) -
Fig.3 - in place.
2. Loosen two capacitor nuts (6)
3. Remove capacitors (7)
(3) (3)
(4)
Fig. 3 Loosening capacitor screws
(5)
(5)
Fig. 4 Loosening capacitor nuts
(7)
(6)

Table of Contents

Other manuals for Fronius TransPuls Synergic 3200

Related product manuals