96
1. Remove both upper copper clips (10)
and (11) from the transformer
2. Loosen screw (12) on the middle tap
connection
1. Loosen hexagon bolt (5) on minus
socket using size 19 spanner
2. Feed out the throttle lead (9) from the
shunt (8)
Removing throttle
(continued)
Fig.4 Loosening hexagon bolt
1. Loosen three screws (13) on throttle
(14)
2. Carefully remove throttle (14) and
throttle lead (15) together
Fig.5 Exposing throttle
Fig.6 Removing throttle
(11)
(10) (12)
(13)
(13)
(15)
(14)
Fitting throttle 1. Feed throttle lead (9) through bushing
(16)
Fig. 7 Feeding throttle lead
(16)
(5)
(6)
(8)(9)
(9)