EasyManua.ls Logo

Fronius TransPuls Synergic 3200 - Device Concept and Application Areas

Fronius TransPuls Synergic 3200
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
EN
Nothing happens
on control panel
(TPS 3200/4000/
5000)
(continued)
Steady +5V, +15V, -
15V on UST?
Check/change control
panel/ribbon cable
Yes
Unplug X4 from UST
No
A
Steady +5V, +15V, -
15V on UST?
Change VAC shunt
Yes
Unplug X2 from UST
No
Steady +5V, +15V, -
15V on UST?
Check/change control
panel/ribbon cable
Yes
Unplug X6 from UST
No
Steady +5V, +15V, -
15V on UST?
Change BPS
Yes
Change UST
No
End
Check cooling unit
Steady +24V int/ext
LEDs on UST?
Change BPS
No
Yes
B