EnE parameter. The value continuously rises during welding in line with the per-
manently increasing energy input. The final value is stored after the end of weld-
ing until welding starts again or the power source is switched back on - the HOLD
indicator lights up.
*) During the MIG/MAG standard synergic welding process and MIG/MAG pulsed
synergic welding process, if one of these parameters is selected, then the syner-
gic function ensures that all other parameters, including the welding voltage para-
meter, are adjusted automatically.
**) In conjunction with the VRD option, the indicator of the currently selected welding
process is also used as status indicator:
- The indicator lights up continuously: the voltage reduction (VRD) is active
and limits the output voltage to less than 35 V.
- The indicator flashes as soon as a welding operation occurs, which can
cause the output voltage to be greater than 35 V.