Set the contact
pressure
1
NOTE!
Set the contact pressure in such a way
that the wire electrode is not de-
formed but nevertheless ensures
proper wirefeeding.
Contact pressure
standard values
Semi-cylindric-
al rolls
Trapeze rolls Plastic rollers
Aluminium 1.5 - 3.5 - 4.5
Steel 3 - 4 1.5 -
CrNi 3 - 4 1.5 -