Frymaster 1814 Series Gas Fryers
Chapter 3: Installation
3-3
3.4 Gas Connections (cont.)
CE Standard for Incoming Gas Pressure
1814G/HD50
Gas Type
G20 G25 G30 G31
Pressure (mbar) 20 20 or 25 28/30 or 50 37 or 50
Non- CE Standard for Incoming Gas Pressure
1814G/HD50
Gas Type
Nat LP
Min Pressure W.C/kpa/mbar 6/1.49/14.93 11/2.74/27.39
Max Pressure W.C/kpa/mbar 10/2.50/25.00 13/3.23/32.38
Korea Standard for Incoming Gas Pressure
1814G/HD50
Gas Type
LNG (Natural) LPG (Propane)
Min Pressure W.C/kpa/mbar 4/1.00/10.00 9.2/2.30/23.00
Max Pressure W.C/kpa/mbar 10/2.50/25.00 13.2/3.30/33.00
DANGER
When pressure-testing incoming gas supply lines, disconnect the fryer from the gas
line if the test pressure is ½" PSI [3.45 kPa (14 inches W.C.)] or greater to avoid
damage to the fryer’s gas piping and gas valve(s).
DANGER
All connections must be sealed with a joint compound suitable for the gas being
used and all connections must be tested with a solution of soapy water before
lighting any pilots.
Never use matches, candles, or any other ignition source to check for leaks. If gas
odors are detected, shut off the gas supply to the appliance at the main shut-off
valve and immediately contact the local gas company or an authorized service
agency for service.
DANGER
"Dry-firing" your unit will cause damage to the frypot and can cause a fire. Always
ensure that melted shortening, cooking oil or water is in the frypot before firing the
unit.
A. Rigid Connections: Check any installer-supplied intake pipe(s) visually and clean
threading chips, or any other foreign matter before installing into a service line. If the
intake pipes are not clear of all foreign matter, the orifices will clog when gas pressure is
applied. Seal pipe joints with a sealant resistive to LP gas. When using thread compound
on gas piping, use very small amounts and only on male threads. Use a pipe thread
compound that is not affected by the chemical action of LP gases. DO NOT apply thread
compound to the first two pipe threads—doing so will cause clogging of the burner
orifices and control valve.