4-9
DISPLAY ACTION
WASTE OIL 26. Press the Waste Oil button.
NONE BULK FRONT DISPOSE
27. Select NONE, BULK or FRONT DISPOSE.
NOTE: Select NONE if disposing oil into an MSDU or other METAL
container. Select BULK if disposing oil into a bulk oil system, which has
large storage oil tanks that are connected to the fryer. Select FRONT
DISPOSE if disposing to a front type of disposal pan.
SETUP COMPLETE RESET THE SYSTEM 28. No action.
29. Press the (check) button.
AUTO TOP OFF VAT 30. Press the Auto Top Off Vat button.
31. Select LEFT VAT or RIGHT VAT for split vats.
ON OFF USER PROMPTED TOP OFF
32. Select ON for auto top off. Select OFF to disable auto top off.
Select USER PROMPTED TOP OFF for to disable auto top off and
prompt the user when to top off. If using user prompted top off, it
has to be enabled on ALL vats. Default is ON.
33. Press the Down arrow button.
USER PROMPTED TOP OFF TIMER
34. Set the time to prompt again after acknowledging a top off prompt.
This setting is only available if USER PROMPTED TOP OFF is
selected in AUTO TOP OFF VAT. (Default is 30 minutes).
ATO DELAY TIME 35. Press the ATO Delay time button.
30 MINUTES
36. Press the time to change the delay time after the top off oil
reservoir has been changed before the system begins to top off.
Press the (check) button. Enter a value greater than 0 for solid
shortening. The default is 30 minutes to allow time for the
shortening to start melting before topping off begins. Set the value
to 0 for liquid shortening.
SETUP COMPLETE 37. No action.
38. Press the smaller (check) button inside the SETUP COMPLETE box.
FILTRATION TIME SETTINGS 39. Press the Filtration Time Settings button.
POLISH TIME
DEEP CLEAN TIME
AUTO FILTER WASH TIME
MAINTENANCE FILTER WASH TIME
40. These settings should only be adjusted if instructed by the factory.
The default settings are:
POLISH TIME -300
DEEP CLEAN TIME -3600
AUTO FILTER WASH TIME -5
MAINTENANCE FILTER WASH TIME -30
Press the back button when complete.
41. Press the Down arrow button.
FILTRATION TYPE 42. Press the Filtration Type button.
SOLID LIQUID
43. Select SOLID if solid shortening is used. Select LIQUID if liquid
shortening is used. Press the back button when complete.
OQS SETUP 44. Press the OQS Setup button if an OQS sensor is installed.
OQS ENABLE/DISABLE
45. Press OQS ENABLE/DISABLE button to enable/disable the OQS
sensor.
ENABLE DISABLE
46. Select ENABLE to enable the OQS sensor or DISABLE to disable the
OQS sensor.