5-2
4. Reinstall the crumb tray at the front of the pan. (See Figure 1)
DO NOT USE FILTER POWDER WITH THE PAD!
5. Push the filter pan back into the fryer, positioning it under the fryer. Ensure “P” is not displayed in the top right
corner of any controller. The filtration system is now ready for use.
DANGER
Do not drain more than one frypot at a time into the built-in filtration unit to avoid overflow and spillage of
hot oil that may cause severe burns, slipping and falling.
DANGER
The crumb tray in fryers equipped with a filter system must be emptied into a fireproof container at the
end of frying operations each day. Some food particles can spontaneously combust if left soaking in certain
shortening material.
WARNING
Do not bang fry baskets or other utensils on the fryer’s joiner strip. The strip is present to seal the joint
between the fry vessels. Banging fry baskets on the strip to dislodge shortening will distort the strip,
adversely affecting its fit. It is designed for a tight fit and should only be removed for cleaning.
5.3 Filtration Menu
The filtration menu selections are used for filtering, draining, filling, disposing and cleaning the vats.
The filtration menu is listed below:
Auto Filtration page 5-2
Auto Demand Filtration page 5-3
Maintenance Filter page 5-5
Dispose Oil (Non-Bulk Systems) page 5-6
Dispose Oil (Bulk Systems) page 5-7
Drain Oil page 5-9
Fill Vat from Drain Pan page 5-10
Fill Vat from Bulk (Bulk Only) page 5-11
Oil Pan to Waste (Bulk Only) page 5-11
Deep Clean (Non-Bulk Systems) page 5-13
Deep Clean (Bulk Systems) page 5-15
5.3.1 Auto Filtration
Auto Filtration is a feature that, after a number of preset cook cycles or time, will automatically prompt to filter the
frypots. This function can also be performed on demand as well and is covered in the next section. Note:
Simultaneous filtering of multiple vats does not occur.
DISPLAY ACTION
FILTRATION REQUIRED - FILTER NOW?
1. Press the √ (check) button to start filtration. If the X button is
selected, filtering is cancelled, and the fryer resumes normal
operation. The filter button will turn yellow until the fryer is
filtered. The controller will prompt again soon to filter the oil.
This sequence repeats until a filter is completed.
OIL LEVEL TOO LOW
2. Displayed if the oil level is too low. Press the √ (check) button to
acknowledge issue and return to idle cook mode. Check to see
if the JIB is low on oil. If JIB is not low and this continues to
occur, contact your FAS.
SKIM DEBRIS FROM VAT -
PRESS CONFIRM WHEN COMPLETE
3. Skim the crumbs from the oil with a front to back motion,
removing as many crumbs as possible from each vat. This is
critical to optimizing usable oil life and quality in the oil. Press
the √ (check) button when complete.