7-7
PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
Frypot won’t fill.
A. Incorrect setup procedure.
B. Dispose valve not completely closed.
C. Bulk oil tank is empty.
D. RTI pump issue.
A. Power cycle fryer by disconnecting and
reconnecting 5-pin bulk oil control power
cord on rear of fryer.
B. Ensure the dispose valve handle is pushed
fully closed.
C. Call your bulk oil provider.
D. Call you FAS for assistance.
7.6 Error Log Codes
See section 4.13.2.1 for instructions to access the Error Log.
Code ERROR MESSAGE EXPLANATION
E13 TEMPERATURE PROBE FAILURE TEMP Probe reading out of range
E16 HIGH LIMIT 1 EXCEEDED High limit temperature is past more than 410°F
(210°C), or in CE countries, 395°F (202°C)
E17 HIGH LIMIT 2 EXCEEDED High limit switch has opened.
E18 HIGH LIMIT PROBLEM
DISCONNECT POWER
Vat temperature exceeds 460°F (238°C) and the
high limit has failed to open. Immediately
disconnect power to the fryer and call service.
E19 HEATING FAILURE – XXX F or XXX C Heating Control latch circuit failed.
Heat Contactor failed to latch.
E25 HEATING FAILURE - BLOWER The air pressure switch(s) failed to close.
E27 HEATING FAILURE - PRESSURE SWITCH - CALL SERVICE The air pressure switch has failed closed.
E28 HEATING FAILURE XXX F or XXX C The fryer has failed to ignite and has locked out
the ignition module.
E29 TOP OFF PROBE FAILURE - CALL SERVICE ATO RTD reading out of range
E32 DRAIN VALVE NOT OPEN - FILTRATION AND TOP OFF
DISABLED - CALL SERVICE
Drain valve was trying to open and confirmation is
missing
E33 DRAIN VALVE NOT CLOSED - FILTRATION AND TOP OFF
DISABLED - CALL SERVICE
Drain valve was trying to close and confirmation is
missing
E34 RETURN VALVE NOT OPEN - FILTRATION AND TOP OFF
DISABLED - CALL SERVICE
Return valve was trying to open and confirmation
is missing
E35 RETURN VALVE NOT CLOSED - FILTRATION AND TOP
OFF DISABLED - CALL SERVICE
Return valve was trying to close and confirmation
is missing
E36 VALVE INTERFACE BOARD FAILURE - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
Valve Interface Board connections lost or board
failure.
E37 AUTOMATIC INTERMITTENT FILTRATION PROBE
FAILURE - FILTRATION DISABLED - CALL SERVICE
AIF RTD reading out of range.
E39 CHANGE FILTER PAD 25 hour timer has expired or dirty filter logic has
activated.
E41 OIL IN PAN ERROR The system detects that oil may be present in the
filter pan.
E42 CLOGGED DRAIN (Gas) Vat did not empty during filtration
E43 OIL SENSOR FAILURE - CALL SERVICE Oil level sensor may have failed.
E44 RECOVERY FAULT Recovery time exceeded maximum time limit.
E45 RECOVERY FAULT – CALL SERVICE Recovery time exceeded maximum time limit for
two or more cycles.
E46 SYSTEM INTERFACE BOARD 1 MISSING - CALL SERVICE SIB board 1 connection lost or board failure.
E51 DUPLICATE BOARD ID - CALL SERVICE Two or more controllers have the same location
ID.
E52 USER INTERFACE CONTROLLER ERROR - CALL SERVICE The controller has an unknown error.