7-8
Code ERROR MESSAGE EXPLANATION
E53 CAN BUS ERROR - CALL SERVICE Communications are lost between boards.
E54 USB ERROR USB connection lost during an update.
E55 SYSTEM INTERFACE BOARD 2 MISSING - CALL SERVICE SIB board 2 connection lost or board failure.
E61 MISCONFIGURED ENERGY TYPE The fryer is configured for the incorrect energy
type.
E62 VAT NOT HEATING – CHECK ENERGY SOURCE – XXXF
OR XXXC
The vat is not heating properly.
E63 RATE OF RISE Rate of rise error occurred during a recovery test.
E64 FILTRATION INTERFACE BOARD FAILURE - FILTRATION
AND TOP OFF DISABLED - CALL SERVICE
Filtration Interface Board connections lost or
board failure.
E65 CLEAN OIB SENSOR – XXX F OR XXX C - CALL SERVICE Gas -The oil is back sensor does not detect oil.
Clean oil sensor (see section 6.6.2).
E66 DRAIN VALVE OPEN – XXXF OR XXXC Drain valve is opened during cooking.
E67 SYSTEM INTERFACE BOARD NOT CONFIGURED - CALL
SERVICE
Controller is turned on when the SIB board is not
configured.
E68 OIB FUSE TRIPPED – CALL SERVICE The VIB board OIB fuse has tripped and didn’t
reset.
E69 RECIPES NOT AVAILABLE – CALL SERVICE The controller has not been programmed with
product recipes. Replace controller with factory
programmed controller.
E70 OQS TEMP HIGH Oil temperature is too high for a valid OQS
reading. Filter at a temperature between 300ºF
(149ºC) and 375ºF (191ºC).
E71 OQS TEMP LOW Oil temperature is too low for a valid OQS reading.
Filter at a temperature between 300ºF (149ºC) and
375ºF (191ºC).
E72 TPM RANGE LOW The TPM is too low for a valid OQS reading. This
may also be seen with fresh new oil. The incorrect
oil type may be selected in the setup menu. The
sensor may not be calibrated for the oil type. See
oil type chart in instruction document 8197316. If
issue continues contact a FAS.
E73 TPM RANGE HIGH The TPM reading is too high for a valid OQS
reading. Dispose the oil.
E74 OQS ERROR The OQS has an internal error. If issue continues
contact a FAS.
E75 OQS AIR ERROR The OQS is detecting air in the oil. Check the O-
rings and check/tighten prescreen filter to ensure
no air is entering the OQS sensor. If issue
continues contact a FAS.
E76 OQS ERROR The OQS sensor has a communication error. Check
connections to the OQS sensor. Power cycle the
entire fryer battery. If issue continues contact a
FAS.