08-07
1-6. Setting Other Functions
( Factory setting)
Setting Description
Function Number Setting Value
Yes
No
40
00
01
The following settings are also possible, depending on the operating conditions.
Auto Restart
( Factory setting)
Setting Description
Function Number Setting Value
No
Yes
42
00
01
Indoor Room Temperature Sensor Switching Function
(Only for Wired remote controller)
If setting value is “00”,
room temperature is controlled by the indoor unit temperature sensor.
If setting value is “01”,
room temperature is controlled by either indoor unit temperature sensor
or remote control unit sensor.
( Factory setting)
Setting Description
Function Number Setting Value
Standard
Lower control
Slightly warmer control
Warmer control
31
00
01
02
03
1-5. Setting the Heater Room Temperature Correction
Depending on the installed environment, the room temperature sensor may require a correction.
The settings may be changed as shown in the table below.
8-5-2 Switching Remote Control Unit Signal Codes
Confirm the setting of the remote control unit signal code and the printed circuit board setting.
If these are not confirmed, the remote control unit can not be used to operate for the air conditioner.
JM1
JM2
Remote control unit
Signal code
Connect
Disconnect
Connect
Disconnect
A (Primary setting)
b
c
d
Connect
Connect
Disconnect
Disconnect
Jumper wire