EasyManuals Logo

Fujitsu AOU12RLFC Design & Technical Manual

Fujitsu AOU12RLFC
151 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #89 background imageLoading...
Page #89 background image
9. Function settings
To adjust the functions of this product according to the installation environment, various types of
function settings are available.
NOTE:
Incorrect settings can cause a product malfunction.
9-1. Function settings on indoor unit
¢
Models: ARU12RGLX, ARU18RGLX, ARU24RGLX, ARU30RGLX,
ARU36RGLX, ARU42RGLX, and ARU48RGLX
By using some components on the PCB, you can change the function settings.
Related components on the PCB and the applicable settings
Component Setting content
DIP switch100
1
Remote controller address setting
2
3
4
DIP switch101
1 Setting change prohibited
2 Setting change prohibited
3 Fan delay setting
Component location
Components on the indoor unit main PCB used for the function settings are located as shown in
the following figure.
SW100
1 2 3 4
SW101
1 2 3
- 83 -
9-1. Function settings on indoor unit 9. Function settings
DUCT TYPE
ARU12-48RGLX
DUCT TYPE
ARU12-48RGLX

Table of Contents

Other manuals for Fujitsu AOU12RLFC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOU12RLFC and is the answer not in the manual?

Fujitsu AOU12RLFC Specifications

General IconGeneral
BrandFujitsu
ModelAOU12RLFC
CategoryAir Conditioner
LanguageEnglish

Related product manuals