18) Emergency heat
Enables or disables emergency heat input.
Function number Setting value Setting description Factory setting
73
00 Disable
01 Enable
NOTE: When this function is used, IR receiver unit is necessary.
19) Fan delay time
Sets the fan delay time when the heater is turned off.
Function number Setting value Setting description Factory setting
74
00 1 minute
01 50 seconds
02 40 seconds
03 30 seconds
20) External heater use in defrosting
Enables or disables external heater use in defrosting.
NOTE: Inappropriate heater selection may cause cold air in defrosting.
Function number Setting value Setting description Factory setting
75
00 Disable
01 Enable