EasyManuals Logo

Fujitsu ARXG54KHTA Design & Technical Manual

Fujitsu ARXG54KHTA
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
11. Safety devices
Type of
protection
Protection form
Model
AOYG45KRTA
AOYG54KRTA
Circuit
protection
Current fuse
(Main PCB)
250 V, 30 A × 2
250 V, 10 A × 2
Fan motor
protection
Thermal protection program
Activate
150 ±15 °C
Fan motor stop
Reset
120 ±15°C
Fan motor restart
Compressor
protection
Thermal protection program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
Thermal protection program
(Compressor temp.)
Activate
108 °C
Compressor stop
Reset
80 °C or less
Compressor restart
Thermal protection program
(Outdoor temp.)
Activate
-20 °C
Compressor stop
Reset
-15 °C
Compressor restart