WALL MOUNTED TYPE
ASTG09-22LV
WALL MOUNTED TYPE
ASTG09-22LV
CONTENTS OF FUNCTION SETTING
Follow the instructions in the Local Setup Procedure, which is supplied with the remote control, in •
accordance with the installed condition.
After the power is turned on, perform the function setting on the remote control.
The settings may be selected between the following two: Function number or setting value. •
Settings will not be changed if invalid numbers or setting values are selected. •
Functions
1) Filter sign
2) Cooler room temperature correction
3) Heater room temperature correction
4) Auto restart
5) Indoor room temperature sensor switching function
6) Remote controller signal code
7) External input control
1) Filter sign
The indoor unit has a sign to inform the user that it is time to clean the filter. Select the time
setting for the filter sign display interval in the table below according to the amount of dust or
debris in the room. If you do not wish the filter sign to be displayed, select the setting value for
"No indication".
(
... Factory setting)
Setting description Function number Setting value
Standard
11
00
Long interval 01
Short interval 02
No indication 03
Setting description Filter sign interval time
Standard 400 hours
Long interval 1000 hours
Short interval 200 hours
2) Cooler room temperature correction
Depending on the installed environment, the room temperature sensor may require a
correction.
The settings may be selected as shown in the table below.
(
... Factory setting)
Setting description Function number Setting value
Standard
30
00
Slightly lower control 01
Lower control 02
Warmer control 03
3) Heater room temperature correction
Depending on the installed environment, the room temperature sensor may require a
correction.
The settings may be changed as shown in the table below.
(
... Factory setting)
Setting description Function number Setting value
Standard
31
00
Lower control 01
Slightly warmer control 02