- 46 -
WALL MOUNTED
ASU30RLE
Heating thermostat on for humidifier
Example of individual connection
Operation status
The heating thermostat output for CNB01 (1-2 or 1-3 or 1- or 1-5) will be on when comp. on or
external heater on.
The heating thermostat output will be off when comp off and external heater off.
Situation
Indoor unit
Mode
Function
setting
Rotary SW
External output
Heating
thermostat on
no. 60
Heating
thermostat on
Indoor unit fan
operation
status
Example of
individual
connection
5 60-05 7 CN2
Not used
6 60-06 8 CN312
7 60-07 9 CN311
8 60-08 A CN310
External output: Heating thermostat on
Humidifier
Heating operation
Heating thermostat
On output
External heater
output On / Off
Comp. On / Off
On
On
On
On
On
Off
Off
Off
Off
Off
Fan
Cool air prevention