Required parts for group connection
Optional part:
Indoor unit type Communication kit
Wall mounted UTY-XCBXZ2
As for the optional parts, refer to Chapter 13-2. "Others" on page
32.
Service part: Wire with connector (Service part no. 9705932012)
Wiring example for multiple remote control or group control:
Communication kit Wire with connector
Crimping terminal and its insulation cap
Remote controller cable (Locally purchased
)
(Locally purchased)
Indoor unit
Indoor unit
To the other indoor units or
wired remote controller
To the other indoor units or
wired remote controller
NOTES:
Conceal the wirings of the group connection inside of the wall or by means of trunking at the
thickness of 1-mm or more to prevent electrical shocks when getting in touch with the cables
under certain circumstances.
When using the Communication kit for wall mounted type, store the crimping terminals inside
the Communication kit.
In the wireless remote controllers for the group connection, its remote controller address can
be set by its own. For the details, refer to following section “Remote controller address setting
procedure for wireless remote controllers”.
An error is displayed immediately just turning on the power to effect the settings of the group
connection. However the error will automatically disappear when the subsequent function set-
ting is completed.
Bundle the wires with a cable tie to prevent external pressures apply on the crimping termi-
nals. (Ensure that the tensile strength for the splicing position is 10 N or above.)
9-2. Remote controller address setting procedure for wireless
r
emote controllers
1. Enter the function setting mode of the wireless remote controller. For details, refer to "Function
settings" on page 24.
2. Select the function number “00” (Remote controller address setting), and then select any of the
number (Setting value) from 00 to 15. (Factory setting: 00)
- 21 -
9-1. Precautions on creating a group connection 9. Group connection
WALL MOUNTED
ASYG09-14KMCB
WALL MOUNTED
ASYG09-14KMCB

Table of Contents

Other manuals for Fujitsu ASYG09KMCB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG09KMCB and is the answer not in the manual?

Fujitsu ASYG09KMCB Specifications

General IconGeneral
BrandFujitsu
ModelASYG09KMCB
CategoryAir Conditioner
LanguageEnglish

Related product manuals