|Hot-adding disk shelves with IOM12 modules|
3. If you are hot-adding one or more disk shelves to an end—the logical first or last disk shelf—of an existing
stack, complete the applicable substeps for your configuration; otherwise, go to the next step.
If you are... Then...
Hot-adding a disk shelf to an end of a
stack that has multipath HA, multipath,
quad-path HA, or quad-path connectivity
to the controllers
a. Disconnect any cables from IOM A of the disk shelf at the
end of the stack that are connected to any controllers;
otherwise, go to substep e.
Leave the other end of these cables connected to the
controllers, or replace cables with longer cables if needed.
b. Cable the shelf-to-shelf connection(s) between IOM A of
the disk shelf at the end of the stack and IOM A of the disk
shelf you are hot-adding.
c. Reconnect any cables that you removed in substep a to
the same port(s) on IOM A of the disk shelf you are hot-
adding; otherwise, go to the next substep.
d. Verify that all cables are securely fastened.
e. Repeat substeps a through d for IOM B; otherwise, go to
Step 4.
Hot-adding a disk shelf to an end of the
stack in a HX2000 single-path HA or
single-path configuration
These instructions are for hot-adding to
the end of the stack that does not have
controller-to-stack connections.
a. Cable the shelf-to-shelf connection between IOM A of the
disk shelf in the stack and IOM A of the disk shelf you are
hot-adding.
b. Verify that the cable is securely fastened.
c. Repeat applicable substeps for IOM B.
4. If you hot-added a disk shelf with mini-SAS HD SAS optical cables to a stack of disk shelves connected with
SAS copper cables, replace the SAS copper cables; otherwise, go to the next step.
The stack must meet the requirements stated in the “Requirements for hot-adding disk shelves with IOM12
modules” section of this procedure.
5. Download and run Config Advisor to verify that your SAS connections are cabled correctly.
Fujitsu Downloads: Config Advisor
If any SAS cabling errors are generated, follow the corrective actions provided.
6. Verify SAS connectivity for each hot-added disk shelf: storage shelf show -shelf shelf_name
-connectivity
You must run this command for each disk shelf you hot-added.
For example, the following output shows hot-added disk shelf 2.5 is connected to initiator ports 1a and 0d
(port pair 1a/0d) on each controller:
cluster1::> storage shelf show -shelf 2.5 -connectivity
Shelf Name: 2.5
Stack ID: 2
Shelf ID: 5
Shelf UID: 40:0a:09:70:02:2a:2b
Serial Number: 101033373
Module Type: IOM12
Model: DS224C
Shelf Vendor: Fujitsu
Disk Count: 24
Connection Type: SAS
Shelf State: Online
Status: Normal
Paths:
Controller Initiator Initiator Side Switch Port Target Side
Switch Port Target Port TPGN
16

Table of Contents

Other manuals for Fujitsu ETERNUS AX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ETERNUS AX Series and is the answer not in the manual?

Fujitsu ETERNUS AX Series Specifications

General IconGeneral
BrandFujitsu
ModelETERNUS AX Series
CategoryStorage
LanguageEnglish

Related product manuals