EasyManua.ls Logo

Fujitsu Eternus DX600 S3 - Power Synchronized Unit; Figure 57 Power Distribution Unit (AC24 A;200-240 V, 2 U, 16 Outlets); Table 24 Power Distribution Unit (AC24 A;200-240 V, 2 U, 16 Outlets) and Provided AC Cable Specifications

Fujitsu Eternus DX600 S3
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power Distribution Unit (AC24A/200-240V, 2U, 16 Outlets)
There are 16 outlets.
Figure 57
Power Distribution Unit (AC24A/200-240V, 2U, 16 Outlets)
1
1. Outlet (OUTPUT)
The specifications of a power distribution unit and the AC cables that are provided are shown below.
Table 24 Power Distribution Unit (AC24A/200-240V, 2U, 16 Outlets)
and Provided AC Cable Specifications
Item Specifications
Power Voltage AC 200 – 240V
Phase Single
Frequency 50Hz/60Hz
Input cable Connection type
Straight-through n NEMA L6-30P
Length 4m
Quantity 2
Power Synchronized Unit
A power synchronized unit detects changes in the AC power output of the Uninterruptible Power Supply (UPS)
unit that is connected to the server and automatically turns on and off the
ETERNUS DX.
For more details about power synchronized units, refer to "Configuration Guide (Power Synchronized Unit)".