24
2.1 Cleaning Materials
The table below shows the cleaning materials that are used on this scanner.
For details on Cleaner F1, consult the agent where you bought your scanner.
*1) It may take long before the cleaner vaporizes if a large quantity is used. When cleaning the
scanner parts, dampen a cloth with modest quantities of the cleaner. In addition, wipe off the
cleaner completely with a soft lint-free cloth to leave no residue on the surface of the cleaned
parts.
2.2 Cleaning the Scanner
The following parts needs to be cleaned:
• Document holding pad
• Document bed
Cleaning Materials Part No. Remarks
Cleaner F1 PA03950-0352
(*1)
1 bottle (100 ml)
Moisten cloth with this fluid and
wipe the scanner clean.
Cleaning Wipe PA03950-0419 24 sheets/pack
Pre-moistened with Cleaner F1,
Cleaning Wipes are used instead
of moistened cloths.
Soft, dry, lint-free cloth Any commercially available cloth
PFU LIMITED
Any detergent for cleaning windows or glass cleaner can be used instead of
F1 fluid. However, do not use paint thinner or other organic solvents.