5.1 Sense Data
C141-E167 5 - 7
Table 5.2 Sense and subsense codes (2 of 5)
C* Q* Name Explanation
Sense
key
13 00 Sync Byte not found for
Data field
SB (Sync Byte) could not be detected in the Data area. 1, 3, B
14 00 Record entity not found Expected data from a sector was undetected. (LBA compare error
detected by FMT)
1, 3, B
01 Record not found The target data block (sector) could not be detected. 3, B
01 Mechanical positioning
Error
A seek error occurred in the drive. 1, 3, B15
02 Positioning Error detected
by read of medium
LBA did not match due to Cylinder number’s mismatch. 1, 3, B
01 Recovered data with retries A data error was recovered from by reading was retried. 1
02 Recovered data with
positive head offset
A data error was recovered by read retry with offsetting head to
positive direction.
1
03 Recovered data with
negative head offset
A data error was recovered by read retry with offsetting head to
negative direction.
1
06 Recovered data without
ECC: data auto-
reallocated
Automatic alternate allocation was applied without ECC correcting a
data error.
1
17
08 Recovered data without
ECC: recommended
rewrite
Rewriting to the same sector was performed without ECC correcting
a data error.
1
02 Defect list error in primary
list
An error was detected during reading of the defect list (P List). 3
03 Defect list error in grown list An error was detected during reading of the defect list (G List). 3
80 Log information read error An error was detected during reading of statistical information. 3
81 Log information write
error
A write error was detected during writing of statistical information. 3
82 Drive Parameter SA read
Error
An error was detected during reading of SA information (Device
Information)
3
83 Drive Parameter SA write
Error
An error was detected during writing of SA information (Device
Information)
3
19
84 Mode Select SA write
Error
An error was detected during writing of SA information (Mode
Select Paramenter)
3
1A 00 Parameter list length error There is a mistake in the indication of the parameter list page length. 5
01 Primary defect list not found The defect list (P List) header is incorrect. 3
02 Grown defect list not found The defect list (G List) header is incorrect. 3
1C
90 SA information list not
found
The SA information (MODE SELECT parameter) header is
incorrect.
3
00 Miscompare during verify
operation
Comparison of data transferred from the INIT by a VERIFY
command (when the Byte Check mode was specified) with data read
from the disk media was terminated unsuccessfully.
E
E
1D
80 Miscompare during self-
configuration
There is an unmatch to compare read data with write data during
self-configuration.