TROUBLESHOOTING FLOWCHART
LED lamp blinking
Turn power on and check
state of lamp.
Not lighted.
LAMP STATE
Power supply
circuit faulty.
POWER SUPPLY STATE
Replace Power
Supply PCB.
REMEDY
Vs and V
d must be adjusted.
Blinks
continuously.
Power turned off
immediately.
RED
Check 1
Blinks continuously.
Power turned off
immediately.
RED
Check 1
Blinks once
Power turned off
after 10 sec.
RED
Check 2
Blinks twice
Power turned off
after 10 sec.
RED
Check 3
Blinks four times
Power not turned
off, LED blinks only.
RED
Replace Main/Digital
PCB Assy.
Blinks five times
Power not turned
off, LED blinks only.
RED
Replace Video PCB
Assy.
Is on-screen display
normal?
All input image
faulty.
Signal processing
PDP panel faulty.
Video PCB faulty.
Video PCB faulty.
PCB faulty.
Signal processing
PCB faulty.
Replace Main/Digital
PCB Assy.
Replace PDP panel
Replace Main/Digital
PCB Assy.
Replace Video PCB
Assy.
Replace Video PCB
Assy.
Video input image
faulty.
S-video input image
faulty.
Component video
input image faulty.
RGB 1,2 input image
faulty.
Check 4
Lights steadily for
more than 10 sec.
GREEN
NO
YES
Note : 1. Protector operates when connector P4(CN4)
is disconnected and power is turn off.
- 13 -

Other manuals for Fujitsu plasmavision

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu plasmavision and is the answer not in the manual?

Fujitsu plasmavision Specifications

General IconGeneral
BrandFujitsu
Modelplasmavision
CategoryMonitor
LanguageEnglish

Related product manuals