RX1330 M3 Operating Manual 27
Noise level
The acoustic noise values are depending on the system configuration.
Electrical values of the PSU
Electrical values of the Fujitsu battery unit (FJBU)
standard fan
configuration
redundant fan
configuration
Sound power level
L
WAd
(ISO 9296)
< 5.2 B (standby)
< 5.3 B (operation)
< 5.4 B (standby)
< 5.4 B (operation)
Sound pressure level at
adjacent workstation
L
pAm
(ISO 9296)
< 34 dB(A) (standby)
< 35 dB(A) (operation)
< 36 db(A) (standby)
< 36 db(A) (operation)
PSU configuration 1x standard PSU or 1x hot-plug PSU or 2x hot-plug
PSUs for redundancy
Max. output 300 W (standard PSU)
450 W (hot-plug PSU)
Rated voltage range 100 V - 240 V
Rated frequency range 47 Hz - 63 Hz
Rated current max. 4.0 A - 2.0 A (100 V - 240 V)
Battery unit
configuration
1x hot-plug PSU in bay 1 and 1x FJBU in bay 2
Max. output 380 W
Backup duration Max. 2 seconds (380W), 4 minutes (280W) with
FJBU M2
Charge duration 4 hours to 90%, 5 hours to 100%
Battery spec. Nickel Metal-Hydrite battery
Battery life time 5 years
Input/Output voltage 12 V DC
Weight 1.2 kg