52 Operating Manual RX1330 M3
Hardware installation
5.3.1 Connecting the monitor
Ê Plug the data cable for the monitor into the video connector on the server
(see figure 4 on page 51).
V CAUTION
The height of VGA cable connectors can vary. Please make sure that the
VGA connector cables do not interfere with the server below.
Ê Connect the insulated connector on the monitor power cable to a grounded
outlet in the rack's socket strip (see also the technical manual for the rack).
5.4 Connecting the server to the mains
In its basic configuration the server has a permanently installed PSU or a hot-
plug PSU. Besides the hot-plug PSU, a second hot-plug PSU can be installed
optionally to serve as a redundant PSU. If one PSU fails, the second PSU in the
redundant configuration ensures operation can continue uninterrupted.
V CAUTION!
The server is automatically set to a mains voltage in the range 100 V -
240 V. You may only operate the server if its rated voltage range
corresponds to the local mains voltage.
Ê Connect the power cord to the server PSU.
Ê Connect the mains connector to an outlet on the rack's socket strip.
I For details, please see the technical manual for the rack.