Do you have a question about the Fujitsu PRIMERGY RX1330 M5 and is the answer not in the manual?
Processor Sockets | 1 |
---|---|
Memory | Up to 128 GB |
Memory Type | DDR4 |
Form Factor | 1U rack server |
Memory Slots | 4 DIMM slots |
Storage | Up to 4x 3.5" or 8x 2.5" drives |
RAID Support | RAID 0, 1, 5, 6, 10, 50, 60 |
Network | 2x 1GbE LAN ports |
Power Supply | 800W |
Provides important information for safely and correctly using the product.
Covers essential safety information, emphasizing that actions must be performed by trained technical specialists.
Explains how to use ServerView Suite and ID indicators for identifying and locating defective servers or components.
Guides on suspending BitLocker functionality and disabling the boot watchdog before maintenance.
Covers updating BIOS/iRMC, verifying backups, updating firmware, reconfiguring software, resetting counters, and enabling components.
Details the procedure for replacing the standard PSU, including preliminary steps and concluding actions.
Covers installing, removing, and replacing hot-plug PSUs, including dummy cover management.
Provides steps for replacing the 4x 3.5-inch HDD backplane, including preliminary steps and concluding actions.
Details the procedure for replacing the left side 4x 2.5-inch HDD backplane, including preliminary steps.
Provides instructions for replacing the right side 4x 2.5-inch HDD backplane, including preliminary steps.
Explains how to replace the 10x 2.5-inch HDD backplane, including preliminary steps and cable disconnections.
Provides steps for replacing a fan module, including preliminary steps and disconnecting/connecting fan cables.
Step-by-step guide for installing memory modules, including selecting slots and handling securing clips.
Instructions for removing memory modules, emphasizing the ejection of modules using securing clips.
Safety precautions for handling CPUs, emphasizing ESD sensitivity and avoiding damage to spring contacts.
Covers CPU handling precautions, preliminary steps, and the process of removing and installing CPUs and heat sinks.
Guides on disconnecting ODD cables, releasing the ODD latch, and pulling the ODD out of its bay.
Details replacing the COP, including notes on system information backup/restore and preliminary steps.
Step-by-step guide for installing the serial interface, including preliminary steps and connecting the cable.
Provides instructions for removing the serial interface, including disconnecting the cable and slot cover.
Safety precautions for handling internal devices and components, emphasizing ESD protection.
Covers TPM installation kit, position on the system board, and procedures for installing and removing the TPM.
Instructions for replacing the system board, including TPM handling and system information backup/restore.