10.2.2 General memory population rules
–
Populate memory slot 1 / channel A (DIMM 1A) first.
–
Within all channels memory slot 1 must be populated prior to slot 2.
–
For maximum performance, populate both channels with the same amount
of memory (symmetric dual channel configuration).
–
If memory modules with dif
ferent capacities are used:
–
Install modules with higher capacities first.
– Within a channel, install modules in descending order of capacity.
–
If memory modules with different speeds are used, the lowest clock rate
applies for all DIMMs.
Channel A B
Slot ID 1A 2A 1B 2B
Dimm# 1 x
Dimm# 2 x x
Dimm# 3 x x x
Dimm# 4 x x x x
Table 3: Mounting order