EasyManuals Logo

Fujitsu PRIMERGY RX4770 M4 User Manual

Fujitsu PRIMERGY RX4770 M4
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
RX4770 M4 Operating Manual 63
Starting up and operation
I Note on CSS and Global Error indicators on the I/O panel
If CSS and Global Error indicators are located in the same place on your
server’s I/O panel, please also check the indicators on the front panel to
determine if a CSS or Global Error event has been detected.
I For further details on detected errors, refer to the System Event Log
(SEL) or use the ServerView Operations Manager or iRMC S5 web
interface.
2ID
blue on
The server has been highlighted using
ServerView Operations Manager, iRMC web
frontend or the ID button on the front panel for
easy identification.
blue
flashing
The server has been highlighted for easy
identification using the iRMC (AVR) with
disabled local VGA output.
3
Global
Error
indicator,
see also
"iRMC-
related
status
signals" on
page 59
off
No critical event detected (non CSS
component).
orange
on
Prefailure event detected (non CSS
component).
orange
flashing
Non CSS component failure detected.
Possible causes:
System is out of the specified range
Defective sensor
CPU error
Error detected by server management
software
4
CSS
indicator
off No critical event detected (CSS component).
orange
on
Prefailure event detected (CSS component).
orange
flashing
CSS component failure detected.
Pos. Indicator Status Description

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX4770 M4 and is the answer not in the manual?

Fujitsu PRIMERGY RX4770 M4 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX4770 M4
CategoryServer
LanguageEnglish

Related product manuals