50 Operating Manual T X100 S2
Installation and operation
Switching the server off
The Power-on indicator (item 4 in figure 4 on page 45) lights up green.
Ê Shut down the operating system properly.
The server is switched off automatically.
I If the operating system does not switch off the server automatically, press
the On/Off button for at least four seconds and/or send a control signal
for power button override.
Other On/Off options
Besides the On/Off button, the server can be switched ON and OFF in the
following ways:
– Timer-controlled switch-on/off
Using the ServerView Operations Manager, you can configure that the
server is switched on/off controlled by the internal timer.
– Ring indicator (from modem)
The server is switched on by an internal or external modem.
– Wake up On LAN (WOL)
The server is switched on by a command via the LAN (Magic Packet
TM
).
– After power failure
The server automatically reboots following a power failure (depending on the
settings in the BIOS).
– Power button override
The system can be switched off by pressing and holding down the On/Off
button (for approximately 4 - 5 seconds). The system remains in Off state.
V CAUTION!
There is a risk that data may be lost.