26 Operating Manual
TX1330 M3
Dimensions / Weight
Ventilation clearance
At least 200 mm on the front and rear.
Ambient conditions
Condensation during operation must be avoided!
Noise level (depending on the configuration)
Tower (W x D x H) 177 x 560 x 455 mm
Rack (W x D x H) 483 x 495 x 174 mm (without projecting parts)
Mounting Depth Rack 543 mm
Weight Approx. 13 - 28 kg
Weight notes Weight may vary depending on actual configuration
Rack mounting kit Rack mounting kit as option
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2) 5°C ... 40°C (with ATD)
10°C ... 35°C (without ATD)
Transport (2K2) -25 °C ... 60 °C
Humidity 10% ... 85% (non condensing)
SATA systems SAS systems
Sound power level L
WAd
(ISO 9296)
< 4.1 B (standby)
< 4.1 B (operation)
< 4.8 B (standby)
< 5.2 B (operation)
Sound pressure level at
adjacent workstation
L
pAm
(ISO 9296)
< 23 dB (A) (standby)
< 23 dB (A) (operation)
< 31 dB (A) (standby)
< 34 dB (A) (operation)