System configurator and order-information guide
PRIMERGY TX150 S8 Status 2016-02-29
A
Floorstand System Rack System
without CPU, Memory and hot plug PSU without CPU, Memory and hot plug PSU - No Rackmount Kit included !
- a CPU has to be configured - a CPU has to be configured - The Rackmount Kit or the
additionally for a base configuration additionally for a base configuration option no Rackmount Kit has
- One memory kit has to be - One memory kit has to be to be ordered separately
configured for a base configuration configured for a base configuration
LFF Base Unit standard S26361-K1424-V101 LFF Base Unit standard S26361-K1424-V501
- 3 std fans and std PSU - 3 std fans and std PSU
- 4-port SAS backplane for 4x 3.5" hot plug SAS - 4-port SAS backplane for 4x 3.5" hot plug SAS
or SATA HDs incl. cables for connection to the
or SATA HDs incl. cables for connection to the
modular or onboard controllers
modular or onboard controllers
LFF Base Unit redundant S26361-K1424-V201 LFF Base Unit redundant S26361-K1424-V601
- 3 std fans plus 1 std fan for redundancy
- 3 std fans plus 1 std fan for redundancy
- 1 hp PSU has to be added - 1 hp PSU has to be added
- 4-port SAS backplane for 4x 3.5" hot plug SAS - 4-port SAS backplane for 4x 3.5" hot plug SAS
or SATA HDs incl. cables for connection to the
or SATA HDs incl. cables for connection to the
modular or onboard controllers
modular or onboard controllers
SFF Base Unit standard S26361-K1424-V301 SFF Base Unit standard S26361-K1424-V701
- 3 std fans and std PSU - 3 std fans and std PSU
- 8-port SAS backplane for 8x 2.5" hot plug SAS - 8-port SAS backplane for 8x 2.5" hot plug SAS
or SATA HDs incl. cables for connection to the
or SATA HDs incl. cables for connection to the
modular RAID controllers modular RAID controllers
SFF Base Unit redundant S26361-K1424-V401 SFF Base Unit redundant S26361-K1424-V801
- 3 std fans plus 1 std fan for redundancy
- 3 std fans plus 1 std fan for redundancy
- 1 hp PSU has to be added - 1 hp PSU has to be added
- 8-port SAS backplane for 8x 2.5" hot plug SAS - 8-port SAS backplane for 8x 2.5" hot plug SAS
or SATA HDs incl. cables for connection to the
or SATA HDs incl. cables for connection to the
modular RAID controllers modular RAID controllers
PRIMERGY SX150 S8 S26361-K1424-V902
PRIMERGY SX150 S8 Universal Storage Server
Cables included in basic unit
hot plug PSU, LFF (3.5") drives, Tower version Cable for CD/DVD is included
All cables for connection of HDD Backplane are included
Cables for USB Backup Drives are automatically provided
if a USB Backup Drive is ordered.
S26361-F3552-E1 S26361-F3552-E1 Only 1 TPM per system.
TPM Module TPM Module Loose delivery for later
Trusted Platform Module on Motherboard Trusted Platform Module on Motherboard integration possible.
Use according to import restrictions Use according to import restrictions
max. 1x per system max. 1x per system
S26361-F3552-L1
TPM Module add-on kit
C B for later integration (loose delivery)
Trusted Platform Module on Motherboard
Use according to import restrictions
Fujitsu PRIMERGY Server 6 of 24