1 ) Indoor room temperature sensor switching function
(Only for Wired remote controller)
The following settings are needed when use the control by Wired remote
controller temperature sensor.
(
...Factory setting)
Setting Description Function No. Setting No.
No
42
00
Yes 01
* If setting No. is “00” :
Room temperature is controlled by the indoor unit temperature sensor.
* If setting No. is “01” :
Room temperature is controlled by either indoor unit temperature sensor
or remote controller unit sensor.
2 )
Setting record
Record the setting change in the following table.
Setting Description Setting No.
Room temperature sensor
switching
After completing the FUNCTION SETTING, be sure to turn off the power
and turn it on again.
11. MANAGEMENT FUNCTION
Restricts the operations of following power-saving functions by non-author-
ized person, and helps more energy-efcient operation of the system.
With the password control, only the administrator can get access to the
function setting.
For the controlled functions, perform the setting change in “Management
function” screen.
Settings Items:
Function
Economy•
Set temp. auto return•
Set temp. range•
Timer
On timer•
Off timer•
Weekly timer•
Auto-off timer•
(Set temp. auto return : Set temperature auto return)
(Set temp. range : Set temperature range)
For the details on each function, refer to “2-2. Setting items in Menu” in the
operating manual.
11.1. Password setting
Preset value of password is “0000”
Change the password as necessary so that the setting change cannot be
done by other than the administrator.
The changed password should be managed properly by the administrator.
A password (4-digit) required when setting up a Management function can
be changed.
1
When [Menu button] is pressed twice while “Monitor” screen is dis-
played, it switches to the “Submenu” screen.
If [Menu button] is pressed while the “Submenu” screen is displayed,
the display returns to the “Monitor” screen.
Back:
Setting:
Date and time
Submenu
[
1/2
]
Monitor
Screen
Filter sign
R.C. sensor control
Room temp. display
Off
Off
Mo
10:00AM
2
When [Initial] is selected in [Submenu] screen, “Initial” screen is
displayed. Enter current password with the [Cursor button], and press
the [Enter button].
Initial
Management
Key lock select Child lock
Submenu
[
2/2
]
Mo
10:00AM
Back:
Setting:
Monitor
3
Select [Password setting (Management)] in the “Initial” screen, and
press the [Enter button].
Mo
10:00AM
Back:
Setting:
Initial
Language
English
Temp. unit
Password setting (Management)
°F
Filter sign
Management
4
Enter current password.
With pressing the [Cursor button (Up/Down)], enter the number. When
you press the [Cursor button (Right)], the cursor moves to next digit.
After you enter the 4 digits, press the [Enter button].
0 0 00
Mo
10:00AM
Cancel :
OK:
Enter current password.
Password setting
-Note-
When you forget a password, please push a [Menu button] and the
[Cancel button] at the same time for 3 seconds. Screen switches to
"Enter new password" screen.
5
Enter new password with same procedure in step 4.
0 0 00
Mo
10:00AM
Cancel :
OK:
Enter new password.
Password setting
Mo
10:00AM
Back:
Setting:
Initial
Language
English
Temp. unit
Password setting (Management)
°F
Filter sign
Management
11.2. Management setting
Management setting is a function that restricts the operation of some func-
tions on this remote controller.
The functions to be restricted are set in this setting, but not in each functional
setting.
Example: To restrict Economy setting to [ON]
Set to [ON] on all the other signal source except this remote controller.
1
When [Menu button] is pressed twice while “Monitor” screen is dis-
played, it switches to the “Submenu” screen.
If [Menu button] is pressed while the “Submenu” screen is displayed,
the display returns to the “Monitor” screen.
Back:
Setting:
Date and time
Submenu
[
1/2
]
Monitor
Screen
Filter sign
R.C. sensor control
Room temp. display
Off
Off
Mo
10:00AM
2
When [Management] is selected in [Submenu] screen, “Management”
screen is displayed. Enter current password with the [Cursor button],
and press the [Enter button].
Initial
Management
Key lock select Child lock
Submenu
[
2/2
]
Mo
10:00AM
Back:
Setting:
Monitor
0 0 00
Mo
10:00AM
Cancel :
OK:
Initial
Enter current password.
Management
Date and time
-Note-
If the entered password is not correct, message “Password is not
correct” is displayed. Enter correct password.