3. SETTING AND ADJUSTMENTS
3-10
[2 NUMBER OF TT]
Set the number of targets that can be acquired, [100] or [MAX] (200). For FAR-2xx7
radar, select [100].
[3 MAX RANGE]
Select the maximum target tracking range, 24 or 32 nm.
[4 QV DISPLAY]
[OFF]: Normal picture,
[ON]: Quantized video. The normal picture is in effect whenever the power is turned
on regardless of this setting.
[5 QV ECHO LEVEL]
Set the detection level of echoes. The setting range is 1 to 31.
[6 ACQ PRESET]
Show the [ACQ PRESET] menu.
• [LAND SIZE]: Set the land size in units of 100 m.
The setting range is 100 to 3000 m. A target
whose length is equal to or greater than the
length set here is judged as a land target.
• [ANT SELECT]: Set the antenna radiator type of
your radar. The size of the echo changes with ra-
diator size. Select the correct radiator type to en-
sure proper performance.
• [AUTO ACQ CORRE]: Set the correlation count
of automatic acquisition. The setting range is 3 to
10.
• [AUTO ACQ WEED]: Set the cancel count of au-