3. ADJUSTMENTS
20
3.2 How to Set the Time
On the [Menu] window, select [System] → [Ship’s Time] to set the time.
Select [External] to use time data from equipment
that outputs time in ZDA format.
• [Time]: Select the source of time, [UTC] or [Local].
[Depth
Accuracy]
Select the method for measuring depth, [Normal] or [High]. [High] pro-
vides depth with higher resolution.
[Alert] [Alert Mode Select]:
Select the alert mode among [Legacy], [Alert I/
F1] and [Alert I/F 2]. If IF-2503 is connected to FE-800, select [Lega-
cy].
• [Legacy]: Use IIalr and IIals sentences.
• [Alert I/F 1]: Use ALR and ACK sentences.
• [Alert I/F 2]: Use ALF and ACM sentences.
[Buzzer]:
Set [ON] to sound the alarm against alarms other than the
depth alarm.
[Time Adjust] Select the source for time, internal clock or external equipment.
[I/O] [EXT EQUIP]:
Select the source of position data, among [DE], [GA],
[GL], [GN], [GP], [II], [IN], [LA], [LC] or [ALL] (default setting: [GP]).
Note: [ALL], which selects the source in priority order, does not com-
ply with IEC standards.
[Port1], [Port4]:
Set the IEC standard to use for input and output sig-
nals. See section 3.4.
[Port Monitor]:
Show the port monitor.
[Ethernet]:
Set up the Ethernet. See section 3.5.
[Network] [IP ADD]:
Set the [IP address], [Subnet Mask] and [Default Gateway].
[SFI]:
Set the System function ID (SFI) of FE-800 and the external
equipment connected. This SFI must be a unique on network
IEC61162-450. Enter the four-digit number that follows “SD”.
Note: The ID must include “SD” to comply with IEC standards.
[LCD Reset] Reset the working hours of LCD.
[TEST] [Self TEST]:
Show the self test screen.
[LCD TEST]:
Show the LCD test screen.
[Buzzer TEST]:
Select this menu then the buzzer sounds if it is work-
ing properly. To stop the buzzer, press the ENT key.
[DEMO]
Activate the demonstration mode. appears at the bottom-right
corner of the screen when the demonstration mode is turned on.
[Service Reset] Reset the menu settings to the default settings. The confirmation
message appears then select [Yes] to reset the settings.
[Exit] Exit the [Service Menu] then restart the system.
Menu Contents
SIM