AP-2
APPENDIX 2 DIGITAL INTERFACE
I/O Sentences
Note 1: ACK and ALR sentences are available when [Mode] in the [Alert] menu is set to
[Alert I/F 1].
Note 2: ACM, ACN, ALC, ALF, ARC and HBT sentences are available when [Mode] in the [Alert]
menu is set to [Alert I/F 2].
Input sentences
ACM, ACK, ACN, GGA, GLL, HBT, RMA, RMC, VTG, ZDA
Output sentences
ALC, ALF, ALR, ARC, DBK, DBS, DBT*
2
, DPT, HBT, Pfec SDmsi*
1
*1: Mandatory, for multiple (more than one) transducer installation.
*2: Only please use if transducer and keel same level.
Transmission interval
1 s for any sentence other than ALC, ARC and HBT (At 30 seconds interval for ALC, at 50 sec-
onds interval for HBT)
Note: ALF, ARC and ALR are transmitted when occurs events. For ALR, it can be transmitted
at 30 seconds interval.
Data transmission
Data is transmitted in serial asynchronous form in accordance with the standard referenced in
2.1 of IEC 61162-1. The first bit is a start bit and is followed by data bits, least-significant-bit as
illustrated below.
The following parameters are used:
Baud rate: 4800
Data bits: 8 (D7 = 0), parity none
• Stop bits: 1
Data sentences: Input
Data format is IEC 61162-1 Edition 4 unless noted otherwise.
ACM/ACN: Alert command
D0 D1 D2 D3 D4 D5 D6 D7
Start bit
Stop bit
Data bits
$**ACN,hhmmss.ss,aaa,x.x,x.x,c,a*hh<CR><LF>
1 2 3 4 5 6
1. No use
2. Manufacturer mnemonic code (3 digit alphanumeric code), null
3. Alert identifier (0 to 999999)
4. No use
5. Alert command (A=ACK from ext. equipment, Q=Request from ext.
equipment, O=Responsibility transfer, S=Silence from ext. equipment)
6. Sentence status flag (C should not be null field. Sentence without C
is not a command.)