2. WIRING
18
2.6 Bridge Alert Management (BAM) Connection
The power fail alarm can be output by connecting the Transceiver unit to the ship’s
alert system or switchboard that can generate this type of alarm.
Connect the TTYCSLA-1 cable between CN14 in the transceiver unit and the alert
system of the ship referring to the schematic diagram at the end of this manual.
2.7 Junction Box (Option)
Junction boxes are connected between the Transceiver unit and the Matching box as
necessary.
TTYCSLA-1
1
2
3
NORMAL CLOSE
NORMAL OPEN
RELAY COMMON
CN14
Select either one.
Alert System