EasyManua.ls Logo

Furuno FE-800 - Power Supply Requirements; Environmental Conditions; Unit Color Specifications

Furuno FE-800
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FURUNO
FE-800
SP - 2 E2384S01P
220401
3.2 Data sentences (IEC61162-1/450)
Input ACK, ACN, DDC*
3
, GGA, GLL, HBT, RMA, RMC, SRP*
4
, VTG,
ZDA
Output ALC, ALF, ALR, ARC, DBK*
1
, DBS*
1
, DBT*
2
, DDC*
3
, DPT, HBT,
SRP*
4
*
1
: Not SOLAS compliant. *
2
: Available when the transducer face is same level as keel.
*
3
: Available when [Dimmer Control] is set to ‘ON’. *
4
: for IEC61162-450 only
3.3 Output proprietary sentence
PFEC msi (mandatory, for multiple transducer installation)
3.4 IEC61162-450 Transmission group (Datagram type: UdPbC only)
IN MISC, NAVD, NETA, CAM1, CAM2
OUT Arbitrary (default: NAVD)
3.5 Other network functions except IEC61162-450
SSDP, HTTP, Syslog, Furuno management Protocol (FMP),
Optional data recording software communication protocol
3.6 Alarm output Contact closure, Normal open/close (24 VDC/ 2 A)
4 POWER SUPPLY
4.1 Transceiver unit 100-230 VAC: 0.7-0.4 A, 1 phase, 50-60 Hz
4.2 Display unit 24 VDC, 0.4 A (supplied from transceiver unit)
4.3 Printer (option) 12-24 VDC: 1.3 A max. (for printing)
5 ENVIRONMENTAL CONDITIONS
5.1 Ambient temperature -15°C to +55°C
5.2 Relative humidity 93% or less at +40°C
5.3 Degree of protection
Transceiver unit IP22: Bulkhead mount, IP20: Tabletop mount
Display unit IP22
Matching box IP45
5.4 Vibration IEC 60945 Ed.4
6 UNIT COLOR
6.1 Transceiver unit N2.5
6.2 Display unit N2.5