2. OPERATION
2-26
2.22.2 How to stop the audio alarm
When a target enters (or exits) the target alarm zone, the target flashes and the alarm
sounds. The alarm message appears at the bottom of the screen. To stop the audio
alarm, press any key. When the target enters (or exits) the target alarm zone again,
the audio alarm sounds.
2.22.3 How to select the alarm type
You can set the target alarm to activate against targets entering or exiting the alarm
zone.
[In]: The alarm sounds against targets entering a target alarm zone.
[Out]: The alarm sounds against targets exiting a target alarm zone.
1. Press the MENU key to open the menu.
2. Press or to select [Alert Settings], then press the ENTER key.
3. Press or to select [Target Alarm 1] or [Target Alarm 2] then press the ENTER
key.
4. Press or to select [In] or [Out], then press the ENTER key.
5. Press the MENU key to close the menu.
“In” target alarm
“Out” target alarm