2. OPERATION
2-51
6. Set the start point of the sector, then press the ENTER key.
7. Press or to select [Sect-Blank 1 (or 2) End], then press the ENTER key.
8. Set the end point of the sector, then press the ENTER key.
Note 1: You can not set the sector more than 180 degrees.
Note 2: You can not set the total width of sector 1 and sector 2 more than 270
degrees.
9. Press the MENU key to close the menu.
As shown in the following illustration, dashed lines mark the start and end points of the
sector.
2.39 Other Menu Items
This section describes the menu items not previously described.
2.39.1 Brill/Color menu
[Echo Brill]: Adjust the brilliance of echoes (Setting range: [1] to [8]).
Note: Unavailable when [Display Color] is set to [Custom].
[Rings Brill]: Adjust the brilliance of the range rings (Setting range: [Off], [1] to [4]).
[Mark Brill]: Adjust the brilliance of all marks (Setting range: [1] to [4]).
[HL Brill]: Adjust the brilliance of the heading line (Setting range: [1] to [4]).
[Character Brill]: Adjust the brilliance of all characters (Setting range: [1] to [4]).
[Trail Brill]: Adjust the brilliance of trails (Setting range: [1] to [4]).
[L/L Grid Brill]: Adjust the brilliance of L/L grid (Setting range: 1 to 4).
[Chart Brill]: Adjust the brilliance of chart (Setting range: [1] to [4]).
+
Area of no
transmission
Start bearing
of sector
End bearing
of sector