EasyManua.ls Logo

Furuno GP-1670F - Page 169

Furuno GP-1670F
209 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13. INSTALLATION
13-21
If the external source is a FURUNO make, its name appears below [Auto]. Se-
lect the device name to have the device feed respective data.
4) Other items are selected to [Auto]. Respective data are input if associated de-
vice is connected to the system.
5. Press the ESC/MENU key to return to the [INTERFACE] menu.
6. Use the RotoKey
TM
to select [SELECT OUTPUT PGN] then push the key.
7. Use the RotoKey
TM
to select an item then push the key.
8. Select [On] or [Off] as appropriate then push the RotoKey
TM
.
9. Repeat steps 7 and 8 for remaining items.
10. Press the ESC/MENU key several times to close the menu.
CAN bus (NMEA 2000) input/output
Input PGN
PGN Description
059392 ISO Acknowledgement
059904 ISO Request
060928 ISO Address Claim
061184 Self Test Group Function
126208 NMEA-Request Group Function
NMEA-Command Group Function
NMEA-Acknowledge Group Function
126992 System Time
126996 Product Information
127245 Rudder
127250 Vessel Heading
127251 Rate of Turn
127258 Magnetic Variation
127488 Engine Parameters, Rapid Update
127489 Engine Parameters, Dynamic
127493 Transmission Parameters
127496 Trip Parameter, Vessel
127505 Fluid Level
(MAG. VARIATIONS)
(POSN RAP. UP)
(COG/SOG RAP. UP)

Table of Contents