SP - 2 E4429S01A
4.7 Electronic Chart Card C-MAP NT+/MAX chart SD card
5 INTERFACE
5.1 Input data sentences IEC61162-1 and NMEA 0183 Ver1.5
DBT, DPT, MTW, TLL, WPL, VHW, HDT, HDG, DSC, MWV
5.2 Output data sentences IEC61162-1 or NMEA 0183 Ver1.5 selected on menu
$GPAAM, $GPAPB, $GPBOD, $GPBWC, $GPBWR, $GPGLL,
$GPGTD, $GPHDG, $GPGGA, $GPRMA, $GPRMB, $GPRMC,
$GPVTG, $GPXTE, $GPZDA, $GPWPL, $GPMWV, $GPVHW,
$GPTLL, $GPRTE, $GPMTW
6 POWER SUPPLY
6.1 Display Unit 12-24 VDC: 1.5-0.8 A
7 ENVIRONMENTAL CONDITION
7.1 Ambient Temperature Antenna Unit: -20°C to +70°C
Display Unit: -15°C to +55°C
7.2 Relative Humidity 95% or less at 40°C
7.3 Water proofing Antenna Unit: IPX6
(IEC60529) Display Unit: IPX5
7.4 Vibration IEC 60945
8 COATING COLOR
8.1 Antenna Unit N9.5 (white)
8.2 Display Unit Cover: 2.5GY5/1.5, Panel: N3.0