1. INSTALLATION
1-4
7. Fasten the antenna unit to the mounting location with the three sets of supplied
upset screws (M520, flat and spring washers attached) from the bottom through
the mounting holes at step 2. After fastening the screws, coat the screw heads
with the supplied adhesive.
Note: Screw length is dependent on the thickness of the mounting platform.
1.3 Pole Mount
Combine the antenna unit with the pole mount kit then attach the antenna unit assem-
bly to the mounting pole.
1.3.1 Installation notices
The diameter of the mounting pole must be 25 to 50 mm.
• Use the supplied pole mount kit and the supplied fixing support fixture for the pole
mount installation so that the bow mark of the antenna unit faces to the bow.
Select the correct clamp size of the pole mount kit fixture considering the diameter
of the mounting pole.
Name Mast diameter Remarks
Hose Clamp For 20A to 25A (25 to 35 mm)
Standard supply with CP20-04603
For 32A to 40A (35 to 50 mm) Optional supply (OP20-52).
M5 upset screw,
w/flat and spring
washers
(3 places)
2 to 10 mm
20 mm
(supplied)
thickness + 8
to 16 mm
(local supply)
Otherwise
Thickness
(mounting plate)
Length of
M5 screw
Adhesive